10,000 oxygen machine of units delivered India. Best Oxygen Generator Price in China. High oxygen purity. Low noise. Easy to use. Delivers up to 95.5% oxygen concentration. OEM&ODM serive、In stock, Fast Shipping、Free Customs Clearance. Medical grade,Dual flow 10L, 10L oxygen concentrator for sale. Yuwell oxygen machineProvide the best price.
Net weight: about 19 kg
Dimensions: 305*308*680 (mm),
Minimum working time: no less than 30 minutes;
Class II equipment, Type B application part;
Continuous operation
Temperature of oxygen outlet < 46 °C;
Non-AP/APG device
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Thank you for purchasing and using our oxygen generator
•Please carefully read this manual before use, in order to correctly operate
•Please properly keep this manual so that you can check it at any time
•Please use this oxygen generator under the guidance of medical staff
The pictures are for reference only.Please refer to the real object
Security profile
warn
Smoking is prohibited during using this product.
Please do not place the fire source in the room of the oxygen generator. Please do not use this product without reading the instructions, you can contact the manufacturer or technical personnel.
Noted: please do arrange another machine to ready if this machine stop or break.
Do not move the machine by pulling the power cord.
Do not drop and plug foreign objects to the exit.
Recommended use of standard nasal tube
When you do not use the machine, please unplug the power supply.
Before use :
Attention for opening the carton:keep the carton,if you do not use the machine right now.
Transportation and storage conditions
Ambient temperature range: -20 °C ~ +55 °C.
Relative humidity range: <93 %, with no condensation.
Atmospheric pressure range: 500 h Pa -1060 h Pa.
Note: The oxygen generator should be stored in a room with no strong sunlight, no corrosive gas and good ventilation. Avoid severe vibration and inverted lying in transportation.
Product intended use
The nasal oxygen cannula is provided by the customers themselves.
Please use the nasal oxygen cannula product with the medical device registration.
The warnings and cautions shown here are used for the correct and safe use of the product, in order to prevent harm or damage to the users or others.
Warnings and notes are as follows:
Dangerous
Smoking is prohibited during the using of this product.
Please do not place the fire source in the room of the oxygen generator.
Legends |
Contents |
Warning |
It is possible to cause casualties if the wrong use is indicated. |
It is possible to cause personnel injury or product damage when it is used incorrectly |
|
© |
Signs indicate mandatory (things that must be observed). The specific mandatory content is represented by text or pattern, and the left figure shows "general mandatory". |
0 |
Signs indicate forbidden (things that must not do). The specific forbidden content is represented by text or pattern, and the left figure shows general forbidden. |
Warning
Please do not use this product without reading the instructions, you can contact the manufacturer or technical personnel.
Accessories warn
Please do not use another Accessories.only can use our factory products. Other factory's products may cause our products damage,do not use.
Noted
Please do arrange another machine to ready ,if this machine stop or break.you can ask your doctors or hospital.
Symbols and meanings related to safety in this machine
Symbols |
Implication |
Symbols |
Implication |
|
Alternating current |
A |
Caution! |
回 |
Devices of class |
l |
Connection (general supply) |
o |
Disconnection (general supply) |
© |
Connection (part of the device) |
o |
Disconnection (part of the device) |
tt |
This side up |
<s) |
No smoking |
|
Non-rainproof |
|
Stacking limit by number |
|
|
! |
Fragile |
|
|
Product features
Oxygen Concentrator
Item NO : MSLBB204
Product technical indicators:
Current overload or loose connection line, machine halt;
High temperature of compressor, machine halt;
Power off, alarm and machine halt;
Ambient temperature range: 10 °C - 40 °C;
Relative humidity < 80 %;
Atmospheric pressure range: 860 h Pa - 1060 h Pa;
Note: The equipment should be placed in normal working environment for more than four hours before use when the storage temperature is lowerthan 5 °C.
18.Temperature of oxygen outlet < 46 °C;
19.Recommendation: The length of the oxygen tube should not exceed 15.2 meters and cannot be folded;
20.Ingress protection rating: IPXO
21Device type: Non-AP/APG device (cannot be used in the presence of flammable anesthetic gas mixed with air orflammable anesthetic gas mixed with oxygen or methylene).Product Structure
Product Composition:
This product mainly consists of oxygen generator, wetting cup and
flowmeter. There should be an atomizing device with atomizing fumction. Scope of application:
Using air 2s material, using the principle of molecular sieve adsorption to raise oxygen in the
air, the oxygen concentration is 93% - 96%. Machimes with atomization fumction can atomize
drugs and then be imhaled by patients.
A The product is not suitable for surgery, frst aid amd serious patients.
Alarm signal
Symbol |
state |
Indicator light |
l/b |
The system is in good condition; the oxygen concentration^82%±3% |
green light |
A |
50%土3%Vthe oxygen concentration <82%+3% |
yellow light |
|
|
red light |
Compressor fault alarm: red light on, continuous "drip" sound, alarm sound, display screen display "E1”, the whole machine stopped Function.
Low flow alarm: When the outlet flow is less than 0. 5L/min, the machine red light flickers, and the display screen shows "E2”, approximately. Shut down after 5 seconds.
Low oxygen concentration alarm: oxygen generator with oxygen concentration less than 50%(+3%) stopped working, red light flashed and accompanied by continuous failure
The alarm sound and the display screen are displayed as "E3”, and the whole machine stops running. When oxygen concentration is more than 82%, I/O indicator lamp (green)
The light is on and the machine is working properly. When 50% (+3%) is less than 82% of oxygen concentration, the yellow light of * indicator* is on.
Communication alarm: sensor communication failure, display display "E4" fault lightsflashing,
and there is an alarm sound, the whole machine shut down.Note: 30 minutes is the best and most
Maintenance
stable state for each start-up of the oxygen generator.
Warning: For the maintenance of oxygen generator, first cutoff the power supply.
First, the power is disconnected and wiped with clean and soft cotton cloth or sponge.
The liquid can not be flowed into the machine.
The cleaning of filter screen and filter felt is very important for protecting compressor and molecular
sieve and prolonging the life of machine. Please change or clean in time.
When the filter felt or filter screen is not installed or wet, the oxygen generator cannot be operated, otherwise the machine will be harmed.
Located in the back shell of the machine, the filter door cover plate is buckled down, then pulled out, the filter door cover is taken out, and the level 1 filter screen is removed. The filter screen should be cleaned according to the actual use time and environment If there is obvious dust, it should be cleaned or replaced immediately.
After the air inlet filter cover plate is removed, the air inlet cover is rotated counter-clockwise. After the air inlet cover is loosened, the air inlet cover can be removed, and the secondary filter felt can be replaced or cleaned in time.
Clean with a light detergent and rinse with clean water. It must be dry before it can be loaded into the machine.
Alarm signal
Wash wetting cup:
The water in the wetting cup should be replaced every day.Wet cup is cleaned once a week, first with detergent, then with clean water to ensure oxygen hygiene.Clean the wetting cup, and also clean the cap of the wetting cup together.
Clean nasal oxygen tube:
Nasal oxygen tube is a disposable product. If it is reused, it should be cleaned after use. It can be soaked in vinegar for 5 minutes and then washed with clean water.
Clean atomizing assembly:
Atomization components are disposable products. If they are reused, they should be cleaned after each use. After the atomization, shut down the oxygen generator, pull out the air duct or the atomization mask, pour out the drug residue inside, soak the atomization device in water for 15 minutes, and then clean.
Matters needing attention
Fault phenomenon |
fault analysis |
、 processing method |
||
Failure red light flashes. With holding continuous alarm sound. Display screen is shown as"E3", the whole machine stopped running. |
Low concentration alarm |
LSee ifthe traffic exceeds the recommended maximum residential traffic.The maximum recommended flow of is:5L/min |
||
Ifthe "E3" alarm still exists in the oxygen generator Please contact supplieror distributor in time |
||||
Failure lights flicker and haveAlarm sound, whole machine shutdown |
Sensor communication failure |
Please contact the supplier or distributor immediately. |
||
phenomenon of breakdown |
Analyses of breakdown |
Processing method |
Trouble shooting
The oxygen generator does networkorthe indicator light is off after turning on the power switch |
1 .The power plug is in bad contact with the power socket. |
1 .Plug the power cord firmly. |
|
2.The outlet has no power output. |
2.Move to a socket with electricity |
|
3.Main board damage |
3.Replaced by professionals |
Afterstarting the running sound of the machine is normal the flow is adjusted normally but there is little or no feeding. |
1.1s there any defect in the oxygen inhaler |
1 .Replace of oxygen inhaler |
|
2.There is a gap between the humidifying cup and the humidifying cup cap .which is not sealed |
2.Renighten the lid of the humidifier or replace the humidifying bottle. |
|
3.The humidifying cup and the machine are not installed in place. |
3.Reinstall humidifier bottles, humidifier botties and machines should be operated horizontally. |
|
4.The humidifying cup inlet sealring is damaged or missing |
4. Reinstall humidifier bottles,humidifier bottles and machines should be operated horizontally. |
Turn on for a while. Machine temperature is very hihg or directly shut down. |
1 .Cbstruction of intake or exhaust |
1 .The oxygen generator should be placedin the ventilation area,and distance to theconcrete walls,and furniture should be at least 10cm. |
|
2.Inlet filter cotton dirty |
2.Check whether the air iniet sponge behind the machine is blocked or dirty and clean up in tiame. |
|
3.Machine trmpenature is too high |
When the machine leaves the factory, there is a high temperature protection device. If the machine stops because of high temperature,turn off the switch and check whether the filter sponge is dirty in the inlet and outlet,or whether the air inlet or outlet is blocked.Wait unti the machine temperature drops, then restart.I |
Regular or slight popping exhaust sound |
Normal |
It is a normal phenomenon that the machine extracts oxygen and excludes other gas,and make noise. |
Previous:Medical Oxygen Generator MSLBB205 for sale|Medsinglong
Next:None