Sign in Register Account

Buying a patient monitor from a reputable medical equipment dealer offers substantial savings. We carry a large selection of patient monitors in every price range. Monitoring options include, non invasive blood pressure (NIBP), invasive blood pressure (IBP), pulse oximetry (SpO2) among others. Furthermore, be sure you check our selection of cheap medical equipment and feel free to call us with any questions.

MSL Display screen vet patient monitor for sale MSLMP06 for sale
Product Name:  Display screen vet patient monitor for sale MSLMP06
Latest Price: US$500-1277/Set
Model No.:  MSLMP06
Weight:  Net weight: Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

12.1" color TFT screen 

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Display screen vet patient monitor for sale MSLMP06

Professional vet patient monitor for sale MSLMP06

12.1" color TFT screen 

Multi‐channel display 
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
 
Alarm review, arrhythmia review 
Patient info. Input 
Anti‐defibrillation design
NIBP over pressure protection
Plug‐in rechargeable battery, AC/DC available. 
Supporting wire or wireless network.
 

portable vet patient monitor for sale MSLMP06

use vet patient monitor for sale MSLMP06

MSL vet patient monitor for sale MSLMP06 Technical Specifications

 
ECG
Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection                     I, II, III, avR, avL, avF, V
Wavef orm                          2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 
Lead selection                     I, II, III,
Wave form                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
 
HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm 
Sensitivity                        > 200 (uVp-p) 
Differential Input Impedance       > 5 MΩ
 
CMRR                   Monitor > 105 dB 
                                   Operation > 105 dB 
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV 
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi. 
ECG Signal Range                   ±8 m V ( Vp-p ) 
 
Bandwidth                           Surgery    1 ~ 20 Hz
                                    Monitor     0.5 ~ 40 Hz
                                    Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                          PNP, PNC,Alarm Available,Review Available
 
 
Respiration
 
Method                           Impedance between R-F(RA-LL)
Differential Input Impedance       > 2.5 MΩ
Measuring Impedance Range          0.3~3 Ω
Base line Impedance Range           200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm 
                                    Neo/Ped 0 ~ 150 Brpm 
                                    Resolution 1 Brpm 
                                    Accuracy ±2 Brpm
 
Apnea Alarm                        10 ~ 40 S
 
 
MSL vet patient monitor for sale MSLMP06
 
 
 
 
NIBP 
 
Method                            Oscillometric
Mode                              Manual, Auto, STAT                        
Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range          40 ~ 240 bpm
Alarm Type                 SYS, DIA, MEAN
 
Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg 
                                    DIA 10 ~ 215 mmHg 
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg 
                                    DIA 10 ~ 150 mmHg 
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg 
                                    DIA 10 ~ 100 mmHg 
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg
 
Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg 
                                 Pediatric Mode 240±3 mmHg 
                                 Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range                  0 ~ 100 % 
Alarm Range                      0 ~ 100 % 
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec. 
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm
                                   
TEMP
 
Channel                          2
Measuring and Alarm Range 0 ~ 50 ℃
Resolution                      0.1 ℃
Accuracy                ±0.2 ℃
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.
 
 
IBP
 
Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg 
                                PA -6 ~ 120 mmHg
                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                P1 / P2-10 ~ 300 mmHg 
 
 
Press Sensor                    Sensitivity 5  uV/V/mmHg
                                Impedance 300-3000Ω
 
Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval        about 1 secretary
Best vet patient monitor for sale MSLMP06
 
   
 
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
 
Cheap vet patient monitor for sale MSLMP06
 

MSL TEAM picture 

MSL TEAM

 

 

MSL customer group photo

 

MSL Certificate

MSL certificate photo

 
 

 

MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods​ arrive destination safely and quickly.

MSL International shipping
 

Welcome to medicalequipment-msl.com,If you have any demand in Patient monitor. Please feel free to

contact cindy@medicalequipment-msl.com

 

 

Product Inquire

Full name:*
Subject:*
Email:*
City:*
Tel:
Phone:
State:*
Message:*
  

Related Products

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp