Touch Screen Multi-Parameter Patient Monitor MSLMP09
	
	12.1" color TFT touch screen
	Windows style, Multi-channel display
	Big font interface
	ST and arrhythmia analysis
	Drug dose calculation and titration table
	OxyCRG dynamic view display
	Respiration monitoring with apnea alarms
	Alarm review, arrhythmia review
	Patient info. Input
	Anti-defibrillation design
	NIBP over pressure protection
	Plug-in rechargeable battery, AC/DC available. 
	Supporting wire or wireless network.
	Cardiotocography, ctg machine, ctg machine price, ctg machine cost.
	 
	 
	Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
	Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.
	 
	 
	SP02
	 
	Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
	Nellcor(TM)  OxiMax(TM) delivers excellent performance,
	even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.
	 
	 
	 
	ETCO2
	 
	Collaborate with Respironics, Plug and Play EtCO2 monitoring.
	CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small,
	durable and lightweight mainstream sensor provides accurate
	and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor
	for monitoting non-intubated patient.
	Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric
	and neonatal patients.
	Cardiotocography, ctg machine, ctg machine price, ctg machine cost.
	 
	 
	 
	Multi Mounting Solutions
	 
	 
	ECG
	 
	Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
	Lead selection                     I, II, III, avR, avL, avF, V
	Wave form                          2 ch
	Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 
	Lead selection                     I, II, III,
	Wavef orm                          1 ch
	Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
	 
	HR and Alarm Range                 Adult    15 ~ 300 bpm
	                                   Neo/Ped    15 ~ 350 bpm
	Accuracy                           ±1% or±1bpm, which is greater
	Resolution                         1 bpm 
	Sensitivity                        > 200 (uVp-p) 
	Differential Input Impedance       > 5 MΩ
	 
	CMRR                    Monitor > 105 dB 
	                                   Operation > 105 dB 
	                                   Diagnosis > 85 dB
	Electrode offset potential         ±300mV 
	Leakage Current                    < 10 uA
	Baseline Recovery                  < 3 S After Defi. 
	ECG Signal Range                   ±8 m V ( Vp-p ) 
	 
	Bandwidth                           Surgery    1 ~ 20 Hz
	                                    Monitor     0.5 ~ 40 Hz
	                                    Diagnostic  0.05 ~ 130 Hz
	Calibration Signal                  1 (mVp-p),  Accuracy:5%
	ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
	 
	ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,
	R ON T, VT>2,BRADY, MISSED BEATS,
	                                          PNP, PNC,Alarm Available,Review Available
	Cardiotocography, ctg machine, ctg machine price, ctg machine cost.
	Respiration
	 
	Method                            Impedance between R-F(RA-LL)
	Differential Input Impedance       > 2.5 MΩ
	Measuring Impedance Range          0.3~3 Ω
	Base line Impedance Range          200~4 KΩ
	Bandwidth                          0.1~2.5Hz
	Resp. Rate                         Measuring and Alarm Range
	                                    Adult 0 ~ 120 Brpm 
	                                    Neo/Ped 0 ~ 150 Brpm 
	                                    Resolution 1 Brpm 
	                                    Accuracy ±2 Brpm
	 
	Apnea Alarm                        10 ~ 40 S
	 
	 
	NIBP 
	 
	Method                            Oscillometric
	Mode                              Manual, Auto, STAT                        
	Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
	Measuring Period in STAT Mode     5 Min
	Pulse Rate Range           40 ~ 240 bpm
	Alarm Type                  SYS, DIA, MEAN
	 
	Professional Patient Monitor MSLMP09 Measuring and alarm range        
	Adult Mode
	                                    SYS 40 ~ 270 mmHg 
	                                    DIA 10 ~ 215 mmHg 
	                                    MEAN 20 ~ 235 mmHg
	                                Pediatric Mode
	                                    SYS 40 ~ 200 mmHg 
	                                    DIA 10 ~ 150 mmHg 
	                                    MEAN 20 ~ 165 mmHg
	                                Neonatal Mode
	                                    SYS 40 ~ 135 mmHg 
	                                    DIA 10 ~ 100 mmHg 
	                                    MEAN 20 ~ 110 mmHg
	Resolution                      1mmHg
	 
	Accuracy                        Maximum Mean error ±5mmHg
	                                Maximum Standard deviation ±8mmHg
	Overpressure Protection          Adult Mode 297±3 mmHg 
	                                 Pediatric Mode 240±3 mmHg 
	                                 Neonatal Mode 147±3 mmHg
	 
	SpO2
	Measuring Range                  0 ~ 100 % 
	Alarm Range                      0 ~ 100 % 
	Resolution                       1 %
	Accuracy                         70% ~ 100%  2 %
	                                 0%  ~  69% unspecified
	Actualization intervalabout      1 Sec. 
	Alarm Delay                      10 Sec.
	Pulse Rate                       Measuring and Alarm Range 20~300 bpm
	                                 Resolution       1bpm
	                                 Accuracy ±3bpm
	                                   
	TEMP
	 
	Channe                          2
	Measuring and Alarm Range 0 ~ 50 ℃
	Resolution                      0.1 ℃
	Accuracy                 ±0.2 ℃
	Actualization intervalabout     1 Sec.
	Average Time Constant           < 10 Sec.
	 
	IBP
	 
	Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
	Measuring and alarm range       ART 0 ~ 300 mmHg 
	                                PA -6 ~ 120 mmHg
	                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
	                                P1 / P2-10 ~ 300 mmHg 
	 
	Press Sensor                    Sensitivity 5  uV/V/mmHg
	                                Impedance 300-3000Ω
	 
	Resolution                      1 mmHg
	Accuracy                        ±2% or 1mmHg which is greater
	Actualization interval         about 1 secretary
	 
	Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
	Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
	
		MSL TEAM picture 
	
		
			
				
					
						
							
						
							 
						
							 
						
							
						
							 
						
							MSL Certificate
						
					 
				 
				
			 
		 
		
		
			
				
					
						 
					
						MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.