Patient monitor | monitor medical MSLMP14

Patient monitor | monitor medical MSLMP14

Patient monitor | monitor medical MSLMP14
Performance Specifications
| Display | 12.1”color TFT |
| Rolling and refreshing waveform display | |
| Resolution: 800×600 | |
| Multi display selectable including: | |
| Standard display | |
| Large-font display | |
| Trend coexist display | |
| OxyCRG dynamic view display | |
| 7 full ECG waveforms display | |
| Bed-to-bed view display(optional) | |
| Trace | 9 waveforms (7 ECG, 1 SPO2 and 1 RESP) |
| Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s | |
| Indicator | Power/battery indicator light |
| QRS beep and alarm sound | |
| Battery | Rechargeable lithium battery, 12v/4AH |
| Max.24 hour for charging, 2 hours for continue working | |
| Trend | Parameter graphic and tabular trends: |
| 5s/piece, 8 hours; | |
| 1min/piece,168 hours(24hour×7days) | |
| 5min/piece, 1000 hours. | |
| Storage | NIBP: 1000 groups |
| Alarm: 200 groups | |
| SD card external storage (optional) | |
| Alarm | User-adjustable High, Medium and Low limits 3-level |
| Audible and visual alarm | |
| Networking | Connected to central monitoring system |
| TCP/IP netting platform | |
| Wifi connector (optional) | |
| Recorder | Build-in, thermal array |
| Plethysmogram caveform:2 /3 channels | |
| Record mode: manual, on alarm, time-defined | |
| Recording width: 50mm | |
| Printing speed: 50mm/s | |
| Recording type | Frozen waveform record |
| NIBP recall record | |
| Trend table record | |
| Alarm record | |
| Fixed -time record |

Patient monitor | monitor medical MSLMP14
Standard parameter
| ECG |
| Lead mode: 5 –lead(R, L, F, N, C) (3/12 lead ECG for optional) |
| Lead selection: I, II, III, avR, avL, avF, V |
| Waveform: 3 and 7 channel selectable |
| Gain selection: 0.5mm/mv,1mm/mv,2mm/mv |
| Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s |
| Heart rate range: Adult: 15~300bpm; |
| Neonate/pediatric: 15~350bpm |
| Accuracy: +1bpm or +1%, which is greater |
| Resolution: 1bpm |
| Filter: surgery mode: 1~20Hz |
| Monitor model: 0.5~40Hz |
| Diagnostic mode: 0.05~130Hz |
| Scaling signal: 1mv, +3% |
| Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
| Alarm range: 15~350bpm |
| S-T segment detection: |
| Measurement range: 2.0mV~+2.0mV |
| Alarm Range: -2.0mV~ +2.0mV |
| Accuracy: -0.8mV ~+0.8Mv |
| Error: +0.02Mv |
| Arrhythmia analysis: YES |
| SPO2 |
| Measurement range: 0~100% |
| Wave speed: 12.5mm/s;25mm/s |
| Resolution: 1% |
| Accuracy: +2% (70-100%); 0-69% unspecified |
| Alarm range 0~100% |
| Lower perfusion situation |
| Pulse Rate(PR) |
| Range: 20~300bpm |
| Resolution: 1bpm |
| Error: +1bpm or +2%, whichever is greater |
| NIBP |
| Method: Digital Automatic oscillometric |
| Operation mode : Manual/Automatic |
| Auto measurement time: Adjustable (1~720min) |
| (1,2,3,4,5,10,15,30,60,90,120,240,480,720min) |
| Measurement Unit: mmHg/Kpa selectable |
| Measurement types: Systolic, Diastolic, Mean |
| Measurement Range: |
| Range of Systolic pressure: Adult: 40~270mmHg |
| Pediatric: 40~220mmHg |
| Neonate: 40~135mmHg |
| Range of mean pressure: Adult: 20~235mmHg |
| Pediatric: 20~165mmHg |
| Neonate: 20~110mmHg |
| Range of diastolic pressure: Adult: 10~215mmHg |
| Pediatric: 10~150mmHg |
| Neonate: 10~100mmHg |
| Over-pressure protection: Double safety protection |
| Resolution: 1 mmHg |
| Alarm: Systolic, Diastolic, and Mean |
| RESPIRATION |
| Method: RA-LL impedance |
| Measurement range: Adult: 7~120rpm; |
| Neonate/Pediatric: 7~150rpm |
| Apnea alarm: YES, 10~40s |
| Resolution: 1rpm |
| Accuracy: +2rpm |
| TEMPERATURE |
| Compatible probe: YSI or CYF |
| Measurement range: 5~50℃ |
| Resolution: 0.1℃ |
| Accuracy: +0.1℃ |
| Refreshing time: about 1 |
| Average measuring time: <10s |
MSL TEAM picture


MSL Certificate

MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.

Welcome to medicalequipment-msl.com.
If you have any demand in medical equipment, please feel free to contact cindy@medicalequipment-msl.com.

Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 18825085969

Connect us in Whatsapp or Facebook Messenger
Messenger