Mindray BS 120 fully blood chemistry analyzer
Chemistry Analyzer
Discrete, random access, fully automated
100 tests per hour, up to 300 tests per hour with ISE
Up to 33 onboard chemistries and 3 ions
Refrigerated reagent compartment
Flexible configuration for sample/reagent positions
Automatic probe cleaning, liquid level detection & collision protection
8 wavelengths: 340~670nm
Automatic dilution for abnormal sample
External bar code reader (optional)
Bi-directional LIS interface
Mindray BS 120 fully blood chemistry analyzer
Chemistry Analyzer
Technical Specifications
System Function:
Automatic, discrete, random access,
STAT sample priority
Throughput: Up to 100 tests/hour (without ISE), up to
300 tests/hour with ISE (3 ions)
Measuring principles:
Absorbance photometry, turbidimetry,
Ion Selective Electrode technology
Methodology: End-point, fxed-time, kinetic, optional
ISE
Single/dual reagent chemistries,
monochromatic/bichromatic
linear/non-linear multipoint calibration
Programming: Open system with user defned profles
and calculations
Reagent/Sample Handling:
Reagent/Sample tray:
Up to 33 positions for sample,
up to 35 positions for reagent;
24 hour non-stop refrigerated
compartment (4~15?C)
Reagent volume:
R1: 180~450μl, step by 1μl
R2: 30~250μl, step by 1μl
Sample volume: 3~45μl, step by 0.5μl
Reagent/Sample probe:
Liquid level detection, collision
protection and inventory checking
Probe cleaning: Automatic washing both interior and exterior
Carry-over < 0.1%
Automatic sample dilution:
Pre-dilution and post-dilution
dilution ratio up to 1: 150
Dilution vessel: Disposable cuvette
External Bar Code Reader (optional):
Used for sample and reagent programming;
Applicable to various bar code systems
including Codabar, ITF (Interleaved Two of
Five), Code128, Code39, UPC/EAN, Code93;
capable to communicate with LIS in a
bi-directional mode
ISE Module (optional):
Measure parameter: K + , Na + , Cl ?
Reaction System:
Reaction rotor: Rotating tray, containing 40 cuvettes
Cuvette: Optical length 5mm
Reaction volume: 180~500μl
Reaction temperature: 37±0.1?C
Mixing system: Independent mixing bar
Optical System:
Light Source: Halogen-tungsten lamp
Wavelength: 340nm, 405nm, 450nm, 510nm,
546nm, 578nm, 630nm, 670nm
Linear range: 0~3.5Abs
Control and Calibration:
Calibration mode: Linear (one-point, two-point and multi-point),
Logit-Log 4P, Logit-Log 5P, Spline,
Exponential, Polynomial, Parabola
Control rules: Westgard multi-rule, Cumulative
sum check, Twin plot
Operation Unit:
Operation system: Windows? XP Professional/Home SP2, Windows? 7
or above Windows? VISTA Home/Business
Interface: RS-232
Working Conditions:
Power Supply: AC 200~240V, 50/60Hz, 800W or
AC 100~130V, 50/60Hz, 800W
Temperature: 15~30?C
Humidity: 35~85%
Water consumption: 2.5L/hour
Dimension: Bench top: 690mm(W)x570 mm(D)x595 mm(H)
Weight: 75 Kg
MSL TEAM picture