Best blood vein finder device price MSL-268 Product Feature
1. It has three modes: normal mode(white light), round mode (green light). and mode of image enhancement and vein depth recognition.
2. It is equipped with table support and stand support, and easy to operate.
3. Vein Depth Recognition: Under Image Enhancement Mode, adjust the sign“+”on the vein, then vein depth Information will be displayed by green light beside the vein. According to Blood vessels from shallow to deep, there will be respectively one, two and three green lights on.
.Basic Parameters
Rated Power : 25 VA
Chargeing rime : 8 h
Bettery : 6000 mAH ≤200 minx
Resolution : <0.3 mm
Alignment Accuracy : <0.3 mm
Optimal imaging distance : 270-330 mm
.Stand Model
Base diameter:D=640mm
Max.height:1425mm
Ufting Height:400mm
Feature:Light,flexible to use,applicable to many places,long range of adjustment,wide coverage
Application scenario:Inpatient rooms,injection rooms,outpatient rooms,department of pediatrics,emergency departments,blood centers
.Table-top
Clamped Base:Applicable to the 10-80mm thick table
Base size:(LxW):l30mm*115mm
Max.height:550mm
Lifting Height:400mm
Feature:Long range of adjustment,wide coverage
Application scenario:Fixed places such as injection
rooms and blood centers
.Clinical Image Picture
The 1st:
Female, 6 years old, the scalp vein is invisible through naked eyes observation.Vein structure is clear in vein finder' s projection image.
The 2st:
Female, 26 years old, height: 158cm,
weight:66kg Back of hand vein is unclear through naked eyes observation. Vein outline and distribution is clear in projection image.
The 3st:
Female, 26 years old, height: 158cm,
weight:66kg Forearm vein is unclear through naked eyes observation.Forearm vein is clear in projection image.
The 4st:
Female, 27 years old. The patient had venous transfusion for 10 minutes in the morning and felt a little pain in the back of hand. Through observation, the nurse doubted liquid extravasation. Through observation of projection image, it showed that blood vessel distribution was unclear and a large area of shadow was in puncture position. It is determined to be liquid extravasation.
The 5st:
Male, 26 days after birth, its blood vessel is too thin to be observed.The scalp vessel, foot vessel are clear in projection image.
The 6st:
Female, 55 years old. Puncture blood' s return was smooth, puncture succeeded and liquid dropping was smooth. After five minutes, the liquid dropped slowly and stopped. Through checking, there was no IȰuid leakage, needle blockade or blood vessel wall sticking. By observing projection image, it was found that the upper end of puncture position had closed, which eventually led to liquid drop blockade.