Clinical & Diagnostics Hematology Blood Analyzers MSLAB07plus
MSL Clinical Hematology Blood Analyzers MSLAB07plus Specification sheet
3-part differentiation of WBC, 23 parameters, single channel counter
Volume measurement by time ,not wrong warning
Adanced valve technology,long life
RS232 interface, PC connecting
up to 60 samples test per hour
Electrical resistance for counting and SFT method of hemoglobin
Low sample consumption : venous 9.8 ul, capillary 9.6 ul, pre-diluted 20 ul for twice testing one time 8.4” color TFT, Windows interface all testing parameter displayed simultaneously
Windows operation system graphical buttons mouse and keyboard operation
Double convolution and intelligent fitting
Automatic diluting , Mixing , rinsing and clog clearing
Automatically sample probe cleanning (inside and outside)
Large storage capacity: up to 10,000 samples +3 histograms
Internal thermal-sensitive printer or external printer.
RS232 interface, PC connecting
MSL Diagnostics Hematology Blood Analyzers MSLAB07plus Main Technical Specifications
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode : double Channel + unique Hemoglobin test system
Sample volume: 9.8μL for Venous and capillary mode, 20μL for pre-diluted mode
Throughput: More than 60 samples per hour, operate 24 hours per day, auto sleeping and waking-up functions
Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation langue: English
QC control : X-B, L-J, X , SD, CV %
Reference Value Setting : Male , Female, Children, Neonate
Input / output : RS232, parallel printer and keyboard
Print : Graphic thermal printer with various printing format, optional external printer
Temperature : 18℃ - 30℃,wet ≤ 10-90%
Power supply : 220 V ±22 VAC, 50±1Hz
Dimension : 33 CM ( L ) * 38 CM ( W ) * 43 CM ( H )
Weight : 20 KG
Cheap Hematology Blood Analyzers MSLAB07plus Precision
Item Measurement range Precision (C.V.)
1)WBC 4.0×109/L~10.0×109/L ≤4.0%
2)RBC 3.50×1012/L~ 5.50×1012/L ≤2.0%
3)HGB 110g/L~160g/L ≤2.0%
4)PLT 100×109/L~300×109/L ≤8.0%
5)HCT 35%~50% ≤3.0%
6)MCV 80fL~100fL ≤3.0%
7) mean corpuscular hemoglobin (MCH)
8) men corpuscular hemoglobin concentration (MCHC)
9) red blood cell distribution width coefficient of variation (RDW -CD)
10) mean platelet volume (MPV)
11) lymphocyte (L% & L#)
12) monocyte (M% & M#
13) granulocyte (G% & G#)
14) RDW-CV, RDW-SD,PDW,PCT,L-PCR
Parameters linear range CV %
1)WBC( 10 9 / L ) 0.0 - 99.9 ≤2%
2)RBC ( 1012 / L ) 0.0 - 9.99 ≤1.5%
3)PLT ( 10 9 / L ) 0-999 ≤4.0%
4)HGB( g/L ) 0.0-300.0 ≤1.5%
5) hematocrit (HCT) ≤3.0%
6) mean corpuscular volume (MCV) ≤3.0%
7) mean corpuscular hemoglobin (MCH)
8) men corpuscular hemoglobin concentration (MCHC)
10) mean platelet volume (MPV)
11) lymphocyte (L% & L#)
12) Mid#, Mid%
13) granulocyte (G% & G#)
14)RDW-CV, RDW-SD,PDW,PCT,L-PCR
please indicate all parameters included in the offer here minimum WBC 3 parts differential minimum 3 histograms
shall have dual sampling mode of both whole blood as well as capilllary vascular efficient work flow control with patient.
selective testing shall be an open system to accept generic reagents and / or local made reagents
al reagent shall be cyanide free with build - in printer with quality control function and reporting with programmable
automatic cleaning and maintenance accept samples with any anticoagukant including EDTA, heparain and citrate acid
data storage of approximately 300 samples.
sample results
approximately 60 samples/hour
with operation menu, reporting possible with interfacing capabilities to external PC built-in printer LIS software or network.
the system offered shall be designed to operate normally under the condition of the purchasers country the conditions include power supply chmate ,temperature humidity ,etc please declare in detain compliance of this item offered with any relevent quality and safety standard RS 232
Temperature : 18℃ - 30℃,wet ≤ 10-90%
power supply : 220VAC ,50Hz
accessories :
start-up reagent as per manufacturer
Best Hematology Blood Analyzers MSLAB07plus Parameters
WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR
3 –histograms : WBC,RBC and PLT
shall have dual sampling mode of both whole blood as well as capilllary vascular efficient work flow control with patient
selective testing shall be an open system to accept generic reagents and / or local made reagents al reagent shall be cyanide free with build - in printer with quality control function and reporting with programmable automatic cleaning and maintenance accept samples with any anticoagukant including EDTA, heparain and citrate acid
data storage of approximately 300 samples.
approximately 60 samples/hour
with operation menu, reporting possible with interfacing capabilities to external PC built-in printer LIS software or network
the system offered shall be designed to operate normally under the condition of the purchasers country the conditions include power supply chmate ,temperature humidity ,etc please declare in detain compliance of this item offered with any relevent quality and safety standard RS 232
power supply : 220VAC ,50Hz
accessories :
start-up reagent as per manufacturer