Fully auto hematology analyzer MSLAB21Plus
1. Advanced Design Excellent Performance
9.6µL venous blood sample, 9.6µL anticoagulant capillary blood, 20µL prediluted capillary blood. One time blood sampling could make two tests under predilted mode.
Intelligent float discriminator. Manual adjust supported
Dual swirling flow and intelligent fitting technology to ensure reliable PLT counting
Module design, separate hydraulic part and circuit, enhanced anti-interference function
Automatic washing of inside and outside surface of probe
Alarm hint if reagent volume is short
2. Simple Operation Low Cost
Automatic dispense, Automatic making dilution inside of instrument, Automatic testing, Automatic cleaning
Windows color operation interface and operated by mouse & keyboard
Adjustable probe. Many kinds of blood sampling container
Automatic sleep and wake up function
Low reagent consumption and low cost
3. Convenient Maintenance Safety & Eco-protection
Automatic & Intelligent function of diagnosis and maintenance
Soak, back & forth flush, real time monitoring function of high pressure burning and automatic block-clearing
Perfect self checking function, Automatic cleaning tubes during power on and power off for reducing the rate of blockage
Fan Shape door for easy maintenance
Eco-friendly design of built-in reagents, saving spce and reducing the rate of reagent contamination
No cyanogen reagents for Eco-protection
4. Perfect Quality Traceable Results
Manual and automatic calibration available
Boasts management system for quality control, nine kinds of control files. Mean value, SD value, CV value are provided. Automatic drawing L-J graph
Provide relevant blood control and calibrator
Furnished with original reagents
ISO9001, CMD, CMC and CE approved
Fully auto hematology analyzer MSLAB21Plus
23 parameters. Throughput:>60T/H
10.4’’ TFT LCD
High accuracy technology for blood processing, only 9.6µL blood sample
Storing 40 thousand samples. Operated by mouse & keyboard
1. Display all the parameters and three histograms in one screen.
2. Several groups of reference values setting
3. Automatic storing 40 thousand samples. Combined search mode as per many conditions
4. Venous blood 9.6µL, anticoagulant capillary blood 9.6µL, prediluted capillary blood 20µL, convenient and reliable blood sampling
5. Eco-protection designed built-in reagent system, saving space and decrease the rate of contamination
Technical Specifications:
Function: Automated WBC 3-differential, 23 parameters with 3 histograms(WBC, RBC, PLT)
Principal: Electronic impedance, SFT method for hemoglobin
Testing Channel: Two channels testing, WBC/HHGB channel and RBC/PLT channel
Parameters: WBC, LYM#, MID#, GRAN#,LYM%,MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, PCT, RDW-CV, RDW-SD, MPV, PDW, P-LCR and WBC, RBC, PLT three histograms
Throughput: >60T/H, 24 hours switch on, automatic sleep and wake up function
Sampling Mode: Optional venous blood, anticoagulant blood and prediluted blood
Sample Volume: Whole blood ≤9.6µL, capillary blood ≤9.6µL, prediluted capillary blood ≤20µL, the sample volume for repeating two times testing and avoiding second sampling
Working Mode: Automatic sampling, detecting automatic testing, furnished with dilutor, no need diluting outside. Automatic dispensing lyse and making second diluting automatically
Block-clearing: Soak and washing back and forth. Real time monitoring function of high pressure burning and automatic block-clearing. Boast the function of monitoring incomplete blockage
Alarm: Automated system diagnosis, self testing, fault alarm and reagent shortage alarm
Automated Maintenance: Automated washing during power on and power off, reducing the blockage rate
Storage: Adopting 2G SD card memory. Automatic storing 40 thousand samples with all parameters and 3 histograms. Combined search mode as per many conditions
Control Mode: Boasts management system for quality control, nine kinds of control files. Mean value, SD value, CV value are provided. Automatic drawing L-J graph. Provide matched blood control
Calibration Mode: Automatic calibration and manual calibration
Reference Value Setting: Man, Woman, Children, Baby and General etc.
Performance: Repeatability Error Linearity Range
WBC <2.0% 0.0~99.9×109/L
RBC <1.5% 0.00~9.99×1012/L
HGB <1.5% 0~300g/L
MCV <0.4% 40~150fL
HCT <1.0% 0.0~100.0%
PLT <4.0% 0~999×109/L
Carry Over: RBC, WBC, HGB<0.5%, PLT<1.0%
Operating Interface: Colorful Windows interface, no need connecting computer. Operating by graphic button with mouse and keyboard
Display: Big size 10.4’’ TFT LCD, all parameters and histograms displayed in the same screen
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Reagents System: Open reagent system. No cyanogen reagents. Provide original reagents.
Connection Port: USB, RS-232, network interface
Power: Maximum 150VA
Environment: Temperature 10℃-35℃. Relative humidity: 10%-90%
Power Supply: 220(1±10%)V, (50±1)Hz. 90V-260V, 50-60Hz broad range power available for different Countries
Dimension: 520mm×460mm×420mm
Weight: 23Kg
MSL TEAM picture
MSL Certificate
MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.