We are one of MSL largest suppliers of testing equipment for field & laboratory use. We offer carry a large selection of Testing equipment such as Blood gas analyzer, Microplate readers, Portable blood analyzer, Blood coagulation analyzer, Blood pressure analyzer, Blood lactate measurement, Microscope, Oscillator etc.
Blood Glucose,Uric Acid and Cholesterol Test,Multifunction Analyzer MSLCLT05 for sale
Product Name:  Blood Glucose,Uric Acid and Cholesterol Test,Multifunction Analyzer MSLCLT05 for sale
Latest Price:
Model No.:  MSLCLT05
Weight:  Net weight: Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

1. Test Sample: Capillary or venous Whole Blood
2. Test Time: GLU 20 seconds, UA 20 seconds, CHOL 60 seconds
3. Measuring Range: GLU 2.2mmol/L ~ 27.8mmol/L
UA 179mmol/L ~ 1190μmol/L CHOL 2.59mmol/L ~ 10.35mmol/L
4. Sample Volume: about 3μl of GLU, about 3μl of UA, about 15μl of CHOL
5. Hematocrit Range: 30 – 55%
6. Storage / transportation environment: -20Degree Celsius~55Degree Celsius,

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Details:

Multifunction Analyzer - Glucose | Uric acid | Total cholesterol
Multifunction Analyzeris applied to monitor the concentration of blood glucose, uric acid, cholesterol in peripheral whole blood or venous whole blood of human body in vitro. This product is only used for daily self-monitoring. The test results cannot be considered as the basis of clinical diagnosis, screening and medication guidance.


Principle of measurement:

The test is based on electrochemical sensor technology. The Analyzer measures the electrical current generated by the reaction of glucose, uric acid and cholesterol with the reagent of the strip, and displays the corresponding blood glucose , uric acid, cholesterol level. The strength of the current produced by the reaction depends on the amount of glucose, uric acid, cholesterol in the blood sample.

Specifications:

1. Test Sample: Capillary or venous Whole Blood
2. Test Time: GLU 20 seconds, UA 20 seconds, CHOL 60 seconds
3. Measuring Range: GLU 2.2mmol/L ~ 27.8mmol/L
UA 179mmol/L ~ 1190μmol/L CHOL 2.59mmol/L ~ 10.35mmol/L
4. Sample Volume: about 3μl of GLU, about 3μl of UA, about 15μl of CHOL
5. Hematocrit Range: 30 – 55%
6. Storage / transportation environment: -20Degree Celsius~55Degree Celsius,