System Type:2nd Generation of MSLCM05
Principles:Microarray Chemiluminescent Immunoassay
Reagents:Sunlant reagent test kit
Speed:720 tests/hour
Operation mode:Fully automatic load sample and biochip, random, batch and emergency priority
Sample position:60 positions. Continuous loading is allowed during the testing process and Emergency priority
Reagent position:18 positions
Loading system:Teflon coated S/R probe with liquid level detection function
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
System Type:2nd Generation of MSLCM05
Principles:Microarray Chemiluminescent Immunoassay
Reagents:Sunlant reagent test kit
Speed:720 tests/hour
Operation mode:Fully automatic load sample and biochip, random, batch and emergency priority
Sample position:60 positions. Continuous loading is allowed during the testing process and Emergency priority
Reagent position:18 positions
Loading system:Teflon coated S/R probe with liquid level detection function
Detection system: CCD with 2 million 800 thousand pixels
Calibration method :5 point calibration
Temperature :30±0.1℃
Precision:The CV of the test should be ≤5%
Operation System:Windows 7
Dimensions:1510 mm×910 mm×1150 mm
Weight :310 kg
Networking:Can be linked with LIS system of the hospital through COM or network card
Environment :Supply Voltage: 220V±22V,50Hz±1Hz, 1500VA;
Temperature : 20℃~26℃
Air pressure: 85 kPa~106 kPa
1.High Throughput:Integrated with 56 lattices,each of which are able to provide finite information
2.Low cost:Routine inspection items integrated in a chip, forming a " lab on chip"and saving raw materials.
3.High Efficiency:Only 180ul blood is required for testing of all combined indices.
4.High Accuracy:Mainstream chemiluminescence method ensuring high sensitivity, wide linearity and excellent repeatability.
5.High Detection Rate:Research achievement of"863” program, optimized combination of indices and coordinated determination to reduce misdiagnosis and missed diagnosis.
6.Automation:Fully-automatic devices saving manual operation and avoiding man-made error.
Previous:Microarray Chemiluminescence Biochip Detection System MSLCM06 with POCT for sale
Next:Blood Glucose,Uric Acid and Cholesterol Test,Multifunction Analyzer MSLCLT05 for sale
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger