Medsinglong other hot sale medical machine for sale
Output pulse width:0.4ms±10%
Single pulse electricity :>7μc
Single pulse power: ≤300mJ
Open-way output peak value:≤500Vp-p
Max output range value:≤40V
Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%.
Treat time:15-65 minutes,error is 1 minute,
It can bear the influence from open circuit and short circuit, the function is no weaken.
When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
Working mode: continuously
Input:≤100VA
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
It is the Obstetrics and Gynecology treatment products, based on low frequency electric therapy theory and actual situation of low frequency pulse current treatment, set up several treatment according to the most optimal manner, controlled automatically by computer chip, stimulate the specific position of the human body by the special treatment of low-frequency,produce physical effect effect on specific parts of the body, and adjust the human body environment, to clear the breast tubes, promote milk secretion. accelerate the recovery of the uterus, promote postpartum urination, reduce postpartum pain,accelerate healing.and so on.
1.Six-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±8%.
2.Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)
3.Output pulse width:0.4ms±10%
4.Single pulse electricity :>7μc
5.Single pulse power: ≤300mJ
6.Open-way output peak value:≤500Vp-p
7.Max output range value:≤40V
8.Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%.
9.Treat time:15-65 minutes,error is 1 minute,
10.It can bear the influence from open circuit and short circuit, the function is no weaken.
11.When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
12.Working mode: continuously
13.Input:≤100VA
1.Lactation lack at Post partum
2.Dredge breast
3.Mammitis
4.The recovery of the uterus
5.Diastasis recti abdominis
6.Chronic pelvic inflammation and vaginal relaxation
7.Retention of urine
8.Postoperative analgesia
9.Pelvic floor muscle repair
10.Body recovery
Previous:Cost effective Automatic Foam Dispenser MSLAP25 for sale | Medsinglong
Next:Buy Portable Postpartum Rehabilitation Instrument MSLPR05
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger