Product Name:  Cost effective Portable Postpartum Rehabilitation Instrument MSLPR02 for sale
Latest Price:
Model No.:  MSLPR02
Weight:  Net weight: Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

Output pulse width:0.4ms±10%
Single pulse electricity :>7μc
Single pulse power: ≤300mJ
Open-way output peak value:≤500Vp-p
Max output range value:≤40V
Output range adjustment: power output range is 0~260, increase or dis crease progressively  in proper sequence, it is steady consecutively, Min output is 2%.
Treat time:15-65 minutes,error is 1 minute,
It can bear the influence from  open circuit and  short circuit, the function is no weaken.
When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output 
Working mode: continuously 
Input:≤100VA   
Working mode: Continuous progress

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Specification of Portable Postpartum Rehabilitation Instrument MSLPR02:

Four-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±5%.
Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)
Output pulse width:0.4ms±10%
Single pulse electricity :>7μc
Single pulse power: ≤300mJ
Open-way output peak value:≤500Vp-p
Max output range value:≤40V
Output range adjustment: power output range is 0~260, increase or dis crease progressively  in proper sequence, it is steady consecutively, Min output is 2%.
Treat time:15-65 minutes,error is 1 minute,
It can bear the influence from  open circuit and  short circuit, the function is no weaken.
When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output 
Working mode: continuously 
Input:≤100VA   
Working mode: Continuous progress

Application  of Portable Postpartum Rehabilitation Instrument MSLPR02:

Lactation lack at Post partum
Dredge breast
Mammitis
The recovery of the uterus
Diastasis recti abdominis
Chronic pelvic inflammation and vaginal relaxation
Retention of urine
Postoperative analgesia
Pelvic floor muscle repair
Body recovery