Product Data:
Storage Temperature:-20~55℃
Operating Temperature:10~40℃
Storage Humidity:15 to 85%RH
Operating Humidity:10 to 90%RH
Battery:DC3V (2PCS AAA)
Weight:156 G
Outer Dimensions:96x43x149MM
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Product Data:
Storage Temperature:-20~55℃
Operating Temperature:10~40℃
Storage Humidity:15 to 85%RH
Operating Humidity:10 to 90%RH
Battery:DC3V (2PCS AAA)
Weight:156 G
Outer Dimensions:96x43x149MM
Measurement Range:35~42℃
Accuracy:34.0℃~42.0℃±0.2℃
Temperature Display Increments:0.1℃
Response Time:1 S
Measuring Distance:5~8CM
Auto Power Off:<15 S
Applications:
1.Target User: Infants, children and adults.
2.Measuring Point: forehead.
3.Applications field: Hospital, clinic, school, institution and families.
A.Preparation
Function setting:
Hold SET button 2 second enter setting mode. LCD display F1 icon,press + button to select function:
Temperature offset → Fever alarm→ Buzzer → Exit.
Mode switch:
Press SET button to switch calibration mode or body/surface temperature mode.
Choice between Celsius and Fahrenheit units:
After powering on, press and hold the SET button for 2 seconds. After F1 appears on the screen,press the SET button twice.After F3 appears on the screen,press the "+" or "-" button to select between Celsius and Fahrenheit.
Taking a Reading:
Press the START button.
The measurement is complete in 1 second with a long beep.
Move the unit away from the forehead and check the measurement result.
The display lights up for 5 seconds.
Notes:
If the result is lower than 37.5°C, appears green black light on the display.
If the result is higher than 38°C, appears red black light on the display.
If the result is between 37.5°C ~ 38°C, appears orange black light on the display.
Using the Memory Function:
This unit automatically stores the last 25 measurement results.
Press + or - button to check the record. If the memory is full, the unit will delete the oldest reading.
B.Caution:
1)Always make sure the probe is clean and undamaged, and the forehead is clean with no sweat,cosmetics, scars, etc.
2)Prior to measurement, ensure that the patient has not taken a bath or exercised within the last 30
minutes, and has remained in a stable environment for at least 5 minutes.
3)It is recommended to perform measurement three times. If the three measurements are different,
select the highest temperature.
4)Hold the unit with the probe 1 to 3 cm away from the center of the forehead.
5)Holding the unit too long in the hand may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
6)Keep still during measurement.
Previous:Infrared Thermometer,No-contact Thermometer MSLUXA04 for sale
Next:Professional Muscular massage fascia gun MSLMJ02 for sale
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger