C-arm x-ray machine is one kind of our x-ray machines, If this could not feed your requirement, just see other x-ray products, such as portable x-ray machine, mobile x-ray machine, x-ray film processor, dental x-ray machine, digital radiography.
The introdution of x-ray machine - Have you ever heard of the story about the discovery of X-ray? How was X-ray discovered? Could you figure out some uses of X-ray machine?...
Properties: Medical X-ray Equipments & Accessories Brand Name: MSL Model Number: MSLCX05 Place of Origin: Guangdong, China (Mainland) |
Packaging Details: standard packing Delivery Detail: 10-15 working days |
million pixels high-definition, high-speed CCD camera,
digital c-arm x-ray machine
Technical parameters and configuration:
Main components |
Technique parameter |
|||
IMD X-ray tube |
Model:MSLCX06 |
Model:MSLCX05 |
||
Power:3.5kW |
Power:5.0kW |
|||
Double focus fixed anode focus: 1.5mm / 0.6mm |
Double focus rotational anode focus: 0.3mm / 0.6mm |
|||
Anode Heat Capacity: 40kHu X-ray tube sleeve heat capacity:667kHu |
Anode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu |
|||
High Voltage X-ray Generator |
Working frequency:40kHz |
|||
Image intensifier |
Toshiba 9"(including 3 fields of view 4.5"/ 6"/9") |
|||
Tube voltage |
Fluoroscopy Radiograph: 40kV-110kV |
Fluoroscopy Radiograph:40kV-120kV |
||
Tube current |
Fluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA Pulse Fluoroscopy :2pps;8mA |
|||
mAs |
1mA.s-250mA.S |
|||
Fluoroscopy mode |
Manual Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy |
|||
Intelligent exposure control |
No matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced. |
|||
Iris beam limiting device |
when not exposure, keep in the state of Iris Beam limiting preview ,when exposure, keep blanking cycle track |
|||
General radiography |
40kV-120kV;1.0mA.s-250mA.s |
step length 1 kV;1.0mA.s |
||
Digital radiography (digital spot film) |
40kV-120kV;Max 16mA |
Common screen film radiography is eliminated. Digital radiography can get better images |
||
C-arm machinery index |
C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm. |
|||
Distance between focus and window>900mm, arc depth>650mm, horizontal moving range :200mm vertical moving range:400mm |
||||
Tilt angle :±12.5° rotation :±180°corner:125°(-35°-- +90°) |
||||
Laser Orientation |
Laser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation. |
|||
Radiography mode |
||||
Image intensifier & Real-time digital image(1.3 million pixel) processing system |
||||
(CCD)Digital video camera |
million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images. |
|||
Image resolution index |
Grey level:10 Resolution:22 lp/cm |
|||
Camera virtual rotation design |
No X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera mechanical rotation |
|||
Image processing system |
1.Real time edge enhancement (sharpening) |
Image sharpening is also called edge enhancement, that is, to make blurry edge of the image clearer |
||
2.Real time adjustment of the window width and window level |
Obtain images by real-time adjustment of window width,window level, displaying images with different brightness. |
|||
3.Real time(static)multiform noise reduction |
Noise reduction, and improve image clarity |
|||
4.Real tim GAIN adjustment |
Can amplify image signal, reduce x-ray dose, suitable for patient with super large size. |
|||
5.Real tim dynamic brightness compensation and R calibration functions |
Through dynamic logarithmic transformation, linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained |
|||
6.Image conversing ,up-down and right-left rotating,and frame freezing |
||||
7.Patient information management ,Clinic report and print |
||||
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk , USB and DVD and printer,meet the need of sharing the network information , communication and storage in hospital |
||||
Display |
Display2 17"TFT-LCD display |
|||
Printer |
Printer Laser / jet Printer |
|||
Standard configuration |
1.Combined tube(5.0kW)IMD |
1 set; |
||
2.Image intensifier (9 inch 3 fields of view) Toshiba |
1 set |
|||
3.C-arm stander (with full C-arm balance system) |
1 set; |
|||