MSL Portable Anesthesia Ventilator MSLGA14 for sale
Product Name:  Portable Anesthesia Ventilator for sale-MSLGA14
Latest Price: US$100-577/Set
Model No.:  MSLGA14
Weight:  Net weight:58 Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

This anesthesia machine consists of a main unit, an anesthetic vaporizer, a flow meter, an anesthesia respirator and a respiratory circuit system.

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Portable Anesthesia Ventilator for sale-MSLGA14

MSL Portable Anesthesia Ventilator for sale-MSLGA14
 
 

MSL Anesthesia Ventilator machine-MSLGA14 Overview

This MSLGA14 Anesthesia Machine is an essential important anesthesia device in an operation room. Its function is to provide
oxygen and anesthetic agent to a patient needing to go through an anesthesia operation and perform ventilation management.
This anesthesia machine is intended for use in children and adults with a body weight heavier than 10kg.
This MSLGA14 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for
preventing
cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using
a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the
whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation
of carbon dioxide by the patient.
 
advanced Anesthesia Ventilator
 
 
Used Anesthesia Ventilator
 

Operating conditions for MSLGA14 Anesthesia Machine:

---------Ambient temperature: 10 ~ 40 ℃ ;
---------Relative humidity: no higher than 80 %;
--------Atmospheric pressure: 860 hPa ~ 1060 hPa.
--------Power requirement: ~220-240V, 50/60Hz, 40VA, to be well grounded.
--------Air source requirement: medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attention: the AC power supply used for the anesthesia machine must be well   grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993,
an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of
Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. 
 
cheap Anesthesia Ventilator for sale-MSLGA14
 
 
Cheap Anesthesia Ventilator MSLGA14 Structural Characteristics and Operating Principles
This anesthesia machine consists of a main unit, an anesthetic vaporizer, a flow meter, an anesthesia respirator and a
respiratory circuit system.
 
 
MSL New Anesthesia Ventilator for sale
 
New Anesthesia Ventilator
 
Anesthesia Ventilator for sale
 

Best Anesthesia Ventilator for sale-MSLGA14 Technical

1 Operating mode: circulatory closed, semi-closed and semi-open.
2 Gas requirement: medical oxygen and laughing gas with a pressure ranging from 0.3MPa to 0.5 MPa.
3 The maximum error of the pressure testing device should not exceed ± (4% of the full scale reading + 8% of the
actual reading).
4 For oxygen and laughing gas, a special pressure regulator with a safety valve will be provided. The exhaust pressure
of the safety valve should not be higher than 6 kPa.
5 Indication range of the oxygen and laughing gas flow meter: 0.1 L/min ~ 10 L/min.
When the flow rate ranges from 10% of the full scale value to 100%, the scale accuracy should be within ±10% of the
indicated value.
6. The flow meter is equipped with an oxygen-laughing gas proportional control device.
When the oxygen concentration in the mixed gas N2O/O2 conveyed by the anesthesia
machine is no lower than 20% (V/V) or the FiO2 is lower than 20%, the machine will emit an
alarm. 
7. When the oxygen pressure of the anesthesia machine is 0.20MPa±0.05MPa, the machine raises a low gas source
pressure alarm which is a high priority alarm, and shuts off the laughing gas conveyed to the common gas outlet.
8. Oxygen Flush:25~75 L/Min;
9. Anesthetic gas concentration adjustment range of vaporizer: 0~5%, relative error ±20 %.
10. The exhaust pressure of the safety valve of the respiratory circuit is no higher than 6 kPa.
11. Anesthesia ventilator
11.1 Respiration Mode:IPPV,SIPPV,Manu
11.2 Respiration Frequency:4~40bpm
11.3 I/E Ratio:1:1.5~1:4
11.4 Tidal Volume:50~1500mL
11.5 Ptr:-10~10hPa
11.6 Controlled ventilation and assisted ventilation switching time: 6s
11.7 Maximum safety pressure:  ≤ 12.5 kPa.
11.8 Pressure limit range: 1~6 kPa
11.9 Airway pressure alarm: adjustment range of upper alarm limit: 0.3kPa ~ 6 kPa, permissible error ±0.2 kPa, or ±15%
(whichever is greater), the machine should immediately raise a high level alarm when the airway pressure rises to the alarm
value; the lower alarm limit ranges from 0.2 to 5 kPa and the permissible error is ±0.2 kPa or ±15% (whichever is greater).
The machine should immediately raise a medium level alarm when the airway pressure drops to the alarm value and such
condition lasts 4 to 15s.
3.11.10 Tidal volume alarm: the upper alarm limit ranges from 50 to 2000ml, the permissible error is ±20%, the adjustment
range of the lower alarm limit is 0~1800ml, the permissible error is ±20% and the machine should raise a medium level alarm. 
3.11.11 Ventilation volume lower alarm limit: the adjustment range is  0~12 L/min , and the permissible error is ±20%. The
ventilation volume upper alarm limit is fixed to be 25 L/min, the permissible error is ±20% and the machine should raise a
medium level alarm.
3.11.12 Power supply fault alarm: the machine should give audible alarm in case of power outage and the alarm should
last more than 120s. 
3.11.13 The silencing time of the audible alarm signal should be less than 120s. The alarm status should not be deactivated
and visual alarm signal should not be intermittent. 
3.11.14 The emergency battery should be a lead acid battery with a rated output voltage of DC 12V. The duration of the operation
of the anesthetic respirator driven by the battery should be more than 60min.
 
 
MSL New Anesthesia Ventilator
 

MSL New Anesthesia Ventilator for sale

Relate hot sale and cheap portable anesthesia machine

 

MSLGA07PLUS MSLPA01 MSLVM14
mechanical ventilation MSLPA01
MSLGA15 MSLVM06 MSLMN31

MSL TEAM picture 

medsinglong certificate

medsinglong After-sales service

Welcome to medicalequipment-msl.com.

If you have any demand in medical equipment, please feel free to contact cindy@medicalequipment-msl.com.

MSL coupon

Product Inquire

Full name:*
Subject:*
Email:*
City:*
Tel:
Phone:
State:*
Message:*
  

Related Products

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp