Anesthesia gas machine is one kind of our anesthesia machine, If this could not feed your requirement, just see other anesthesia machine, such as portable anesthesia machine, anesthesia ventilator, veterinary anesthesia machine.
Introduction of anesthesia machine: Do you want to know the technology of anesthesia machines?...
Portable Mobile medical anesthesia machine for sale with CE approve-MSLGA05
Anesthesia Machine,with its ergonomic design,integrates a concise and smooth structure and high mobility.The microcomputer-controlled Ventilator adopts exported sensors and other components.Its scientific and proper design as well as rigorous production process are what demonstrate the inner quality of Aokai products: mechanical ventilation is made secure and visible by the folded respiratory bellows,and the security of air supply is guaranteed by pneumatic transmission and measurement system.With multiple modern technologies applied,the Anesthesia Machine is both outstanding in performance and versatile in functions.The Ventilator adopts microcomputer control with high-definition 8.4” TFT color LCD display,integrating the functions of respiratory control and displaying the monitoring parameters.It is versatile in function and excellent in performance.
Part of Mobile medical Anesthesia Machine
Main body |
High-strength engineering plastic rack, light, beautiful and corrosion resistant |
Scope of application |
adult, child |
Gas source |
O2: 0.27~0.55MPa N2O: 0.27~0.55MPa |
Flow meter |
O2 : 0.1~1.0L/min 1.1~10L/min N20: 0.1~1.0L/min 1.1~10L/min Air : 0.1~10L/min |
O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. |
|
Flow rate of rapid oxygen supply |
25~75L/min |
Low oxygen pressure alarm (Oxygen Alarm) |
There will be sound alarm when the oxygen pressure < 0.2MPa |
Vaporizer |
it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. |
Respiratory circuit |
working mode: all-close, semi-close, semi-open APL: 0.5~7 kPa |
Respiratory Bellows |
bellows for adults, tidal volume range:0~1500 ml bellows for children, tidal volume range:0~300 ml anyone can be chosen for application as required by the customer |
Part of Ventilator (Ventilator Definition and Ventilator Function) |
|
Display mode |
High-definition 8.4” TFT color LCD screen display |
Ventilation mode |
IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, IMV, VCV, PCV |
Ventilation parameters |
Tidal volume 20~1500 ml Rate 1~99 bpm SIMV rate 2~20 bpm I:E 4:1~1:8 Inspiratory trigger pressure -1.0~2.0 kPa PEEP 0~2.0 kPa Pressure range 1.0~6.0 kPa SIGH 1.5 times the inspiratory time (70-150 adjustable) Inspiratory platform 0~50% |
Parameters for ventilation monitoring |
tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform,PEEP,inspiratory trigger pressure, Inspiratory platform, autonomous inspiratory rate, lung compliance, airway resistance, flow-volume loop, pressure-volume loop |
Monitoring of oxygen concentration |
21%~100% |
Security Alarm System |
|
Oxygen Concentration alarm |
upper limit setting range 21%~100% |
Airway pressure alarm |
low limit setting range 10%~80% upper limit setting range 0.3~6.0 kPa low limit setting range 0.2~5.0 kPa |
Per-minute ventilation volume alarm |
upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min |
Sustained high-pressure alarm |
it will give alarm when stress have consistently been higher than 2.5 kPa |
Suffocation alarm |
it will give sound and light alarm if there is no tidal volume input for 15 seconds |
Power alarm |
|
Power |
AC 220V±10% 50Hz±1Hz (UPS, Storage battery) |
(Mechanical Arms) |
|
(End-expiratory CO2 monitoring) |
|
*Items within brackets are optional. |
MSLGA07PLUS | MSLPA01 | MSLVM14 |
MSLGA15 | MSLVM06 | MSLMN31 |
MSL TEAM picture
Welcome to medicalequipment-msl.com.
If you have any demand in medical equipment, please feel free to contact cindy@medicalequipment-msl.com.
Previous:Selling well MSLGA06 used in hospital surgical operation anesthesia machine
Next:Halothane anesthesia or other gas anesthesia machine - MSLGA04
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger