Support automatic online compensation, offline compensation and visualcompensation toolsSupport project template function, one-click calling of acquisitionconditions/fuorescence compensation
760mm*450mm*470mm(length*width*height),40KG
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Flow Cytometer
We are committed to building a high-end flow cytometer for scientific researchand testing, and strive to become a professional flow cytometry system solutionproviderandleader.
The operation of flow cytometry is simple and efficient, and the detectionresults are accurate, boosting your research.
No. | Usage | Description | Size | Total Volume | Cat.No. | CTN | G.W |
1 | Lymphocyte subsets T |
CD45-FITC | 10T | 50ul | P.04.01.00131 | 380mm*280mm*320mm-CS | 3KG |
2 | CD4-PE-Cy7 | 10T | 50ul | P.04.01.00129 | |||
3 | CD8-PE | 10T | 50ul | P.04.01.00130 | |||
4 | CD3-PE-Cy5 | 10T | 50ul | P.04.01.00128 | |||
1 | Lymphocyte Subsets T/B/NK | CD45-FITC | 10T | 50ul | P.04.01.00131 | ||
2 | CD3-PE-Cy5 | 10T | 50ul | P.04.01.00128 | |||
3 | CD16-PE | 10T | 50ul | P.04.01.00133 | |||
4 | CD56-PE | 10T | 50ul | P.04.01.00134 | |||
5 | CD19-PE-Cy7 | 10T | 50ul | P.04.01.00132 | |||
No. | Usage | Description | Size | Total Volume | Cat.No. | 300mm*250mm*400mm-RT | 18KG |
1 | Sheath fluid | Sheath fluid | 500T | 10L | X.02.00261 | ||
2 | Cleaning Solution | Cleaning Solution | / | 2L | X.02.00262 | ||
3 | Shutdown Solution | Shutdown Solution | / | 2L | X.02.00263 | ||
4 | Hemolysin | Hemolysin | 20T | 20ml | P.04.01.00135 | ||
5 | PBS Buffer | PBS Buffer | 20T | 20ml | P.04.01.00127 |
Oncology and Hematology
Analysis of 6-color human peripheral bloodimmune cell subsetsAnalysis of 9-color human peripheral bloodimmune cell subsets
。Detection of dendritic cells (DC)
Phenotypic characterization of natural killercell(NK)populations
.Characterization of PBMC T cell receptors
Detection of CD62P Platelet Activation
◆Immunology
.Detection of T cell proliferation(CFSE)
.Detection of B-cell antibody class
Nk cell-mediated clearance of spleen cells
. Detection of Treg cell subsets
Stem cells
Flow cytometry analysis of hematopoieticstem cells from mouse bone marrow
Detection of CAR-T extracellular tumor killing
Analysis of mesenchymal stem cells frombone marrow and endometrium of miceFlow cytometry analysis of mousehematopoietic progenitor cells
*Cell biology.Cell activity test
.Cell cycle detection
*Cell proliferation detection
Cell apoptosis detection
Environmental monitoring
Flow cytometric detection ofbacteriallife and death
Absolute count of virus, bacteria andalgae
Detection of bacterial periodic ploidy
*Algae classification and counting
◆Clinical
Lymphocyte subgroup analysis
·HLA-B27 detection
*Monocyte HLA-DR detection
.Detection of neutrophil CD64
*Regulatory T cell detection
T cell activation and diseases
Th1 Th2 detection
.Th17 cell detection
.Blocking Antibody Detection
*Cytokine detection
Platelet-leukocyte adhesion
Platelet autoantibody detection
Platelet activation and diseases
Paroxysmal nocturnal hemoglobinuria
Leukemia immunotyping test
Detection of residual focus of leukemia
.MDS immune typing
"Hematopoietic stem cell count
lymphoma immunotyping
.Detection of cell cycle and ploidy
Main parameter indicators
Laser configuration
Instrument resolution
Fluorescence detection limit
Fluorescence linearity
Detector
Forward scattered light resolution
Detection particle range
Carryover rate
Absolute count
Detection speed
Signal range
Injection speed
Threshold setting
Fluorescence compensation
Project template
Instrument quality control
Main parameter indicators
Up to 3 lasers 405nm(100mW),488nm(60mW),638nm(80mW )
<2%
FITC<50MESF;PE<30MESF;APC<30MESF
≥0.99
APD Detector
<0.45um
0.2-50μm
<0.1%
Compatible with volumetric and microsphere absolute counting
>50000 events/s
Maximum10?
Low:15uL/min;Medium:30uL/min;High1:60uL/min;High2:90uL/min;High 3:120uL/minAdjustable speed range: 15-120 μLmin
Supports dual thresholds to minimize cell debris
Support automatic online compensation, offline compensation and visualcompensation toolsSupport project template function, one-click calling of acquisitionconditions/fuorescence compensation information
Automatic daily QC inspection, tracking and recording through Levery-Jennings
Single tube manual sampling
Injection mode
Software
File format
Maintenance method
Computer configuration
Size and weight
40 tubes auto sampler with single sample mixing function96-hole plates
English interface, support acquisition and analysis at the same time
Support FCS3.1/FCS3.0 and FCS2.0 format files
Startup initialization, startup cleaning, cleaning between experiments,shutdown cleaning,exhaust bubble, etc
Automatic maintenance procedure for monthly cleaning (deep cleaning)
DELL/CPU 15/Memory 8G/HDD 1T/27 inch monitor
760mm*450mm*470mm(length*width*height),40KG
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger