Sign in Register Account

MSL A CT scan has many uses, but is particularly well-suited to quickly examine people who may have internal injuries from car accidents or other types of trauma. A CT scan can be used to visualize nearly all parts of the body and is used to diagnose disease or injury as well as to plan medical, surgical or radiation treatment.

Best Precision 32 Computed Tomograph System MSLCTX10
Product Name:  Best Precision 32 Computed Tomograph System MSLCTX10
Latest Price:
Model No.:  MSLCTX10
Weight:  Net weight: Kg
Minimum Order Quantity:  1 Set Set/Sets
Supply Ability:  300 Sets per Year
Payment Terms:  T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal
Size:  
Color:  
QTY:  

Quick Details

Slip ring  Germany low-voltage slip ring
Aperture Size  715±5mm
Tilt Angulation Range  -30° ~ +30°
Scan localizer  Positioning laser
Slice Thickness  2x1.1mm 8x0.55mm 16x0.55mm 16x1.1mm
Scan time (s/360°)  0.72s, 0.8s, 1.0s, 1.5s, 2.0s
Maximum FOV (Field of View) 500mm
Detector Type  GOS ceramic solid detector
Detector Number  888x24
Detector Row  24
Detector channel per row  888
X-ray Tube

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Features of Precision 32 Computed Tomograph System MSLCTX10:

AccuScan-Enjoy ease
Space saving and cost saving in maintennace
Ahead-Head dual-energy head imaging technology
AccuTilt dual-mode gantry tilt technology
AccuOrgan-Targeted organ imaging
Admir iterative reconstruction technology
AccuDose-Comprehensive low dose imaging

Specification of Precision 32 Computed Tomograph System MSLCTX10:

Slip ring  Germany low-voltage slip ring
Aperture Size  715±5mm
Tilt Angulation Range  -30° ~ +30°
Scan localizer  Positioning laser
Slice Thickness  2x1.1mm 8x0.55mm 16x0.55mm 16x1.1mm
Scan time (s/360°)  0.72s, 0.8s, 1.0s, 1.5s, 2.0s
Maximum FOV (Field of View) 500mm
Detector Type  GOS ceramic solid detector
Detector Number  888x24
Detector Row  24
Detector channel per row  888
X-ray Tube

Tube Type  Varex GS-30719
Focal Spot Size  0.7x0.8; 1.2x1.4
Cooling Method  Oil
Heat Storage Capacity  3.5 MHU
Maximum Anode Cooling Rate 8750W (12250 HU/sec)
Maximum Continuous Anode Heat Dissipation 3400W (4760HU/sec)
High Voltage Generator

HVG Type  Spellman CT70PN42X5245
Maximum Power  42kW
Output Voltage  60kV, 70kV, 80kV, 100kV, 120kV, 140kV
Output Current  10mA ~ 350mA
Maximum  Continuous Exposure Time 100s
Patient Couch

Movement Range  0 ~ 1725mm
Maximum Scan Range  1650mm
Horizontal Speed Range  0.5 ~ 300mm/s
Vertical Range  450mm ~ 920mm
Maximum Load Capacity  205kg
Console (Minimum Configuration Requirement)

CPU  3.5GHz
Hard Drive  3TB
Host Memory  16GB
Image Storage  500GB
Graphics  3G
Display Monitor  LCD 23’ LCD 1920x1080 Resolution
Archive  DVDRW
UPS for console  Configuration
Axial Scan

Scan FOV  500mm
Slice Thickness  8×0.55mm, 16×0.55mm, 16×1.1mm
Image Thickness  0.55mm, 1.1mm, 2.2mm, 4.4mm, 8.8mm
Recon FOV  ≥50mm and ≤500mm
Recon Matrix  512×512, 768×768, 1024×1024
Helical Scan

Slice Thickness  8×0.55mm, 16×0.55mm, 16×1.1mm
Pitch  0.51:1~1.5:1
Image Thickness  0.55mm, 0.8mm, 1.0mm, 1.5mm, 2.0mm,
3.0mm, 4.0mm, 5.0mm, 8.0mm
Max.  Continuous  scan length 1650mm
Max. Continuous scan time  100s
Recon FOV  ≥50mm and ≤500mm
Recon Matrix  512×512, 768×768, 1024×1024

Client Usage Photos of Precision 32 Computed Tomograph System MSLCTX10