This MSLGA17 Anesthesia Machine is an essential important anesthesia device in an operation room. Its function is to provide oxygen and anesthetic agent to a patient needing to go through an anesthesia operation by manual. This model no come with ventilator manage.
| Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Anesthesia Equipment | Anesthesia Machine MSLGA17

Anesthesia Equipment | Anesthesia Machine MSLGA17
This MSLGA17 Anesthesia Machine is an essential important anesthesia device in an operation room. Its function is to provide oxygen and anesthetic agent to a patient needing to go through an anesthesia operation by manual. This model no come with ventilator manage.

| TECHNIQUES SPECIFICATIONS | |
| Physical specifications | |
| Mode | pneumatically driven manual controlled system |
| Screen: | NO |
| Suitable | Adult |
| Mode: | by manual to manage |
| Working Mode: | Closed; Semi-Open |
| Circuit | Breathing circuit integrated standards |
| Tube: | 2 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min |
| Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
| Drawer unit | ONE drawer totally extractable |
| Technical Specifications: | |
| Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
| O2 absorb capacity | 1.5KG |
| Flow meter | O2:0.1~10L/Min, N2O:0.1~10L/Min |
| oxygen concentration in the mixed gas N2O/O2 | > 25% |
| Oxygen Flush: | 25~75 L/min |
| Respiration Mode | Manual |
| Pressure limit range: | 0 ~ 6.0 kPa |
| Alarm | O2 pressure is too low |
| Operating conditions | |
| Ambient temperature: | 10 ~ 40oC |
| Relative humidity: | no higher than 80 % |
| Atmospheric pressure: | 860 hPa ~ 1060 hPa |
| Air source requirement: | Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa. |
| Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
| Configuration: | |
| Vaporizer | Enflurane/ Isoflurane/Sevoflurane(Option: Halothane) |
| Storage | |
| Ambient temperature: | -15oC ~ +50oC |
| Relative humidity: | no higher than 95 % |
| Package | |
| packaging box | comply with the requirement of GB/T 15464 |
| Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation | |
| Moisture protection and rain protection to ensure that product is protected from natural damage. | |
| Safty & Alarm | |
| Alarm | It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa |
| STANDARD CONFIGURATIONS | |
| QTY | NAME |
| 1 set | Main unit |
| 1 set | 2-tube flow meter |
| 1 set | vaporizer |
| 1 set | Patient circuit |
| 1 set | Na lime tank |
| 1 pic | Oxygen pressure reducer |
| 2 pics | A leather bag ( Blue) |
| 4 pics | Threaded pipe |
| 2 pics | mask |
| 1 set | Tools with the machine |
| 1 set | User Manual (English Version) |
| MSLGA07PLUS | MSLPA01 | MSLVM14 |
![]() |
![]() |
![]() |
| MSLGA15 | MSLVM06 | MSLMN31 |
![]() |
![]() |
![]() |
MSL TEAM picture


Welcome to medicalequipment-msl.com.
If you have any demand in medical equipment, please feel free to contact cindy@medicalequipment-msl.com.

Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 18825085969

Connect us in Whatsapp or Facebook Messenger
Messenger