It's used on the course of ventilation treatment of CPAP (Nasal-
CPAP) for premature infant, neonate, infant to children below 14 years old. CPAP mode makes children breath spontaneously and reduces the work of breathing effectively. It applied to the neonate who are at risk of light respiratory failure but can breath spontaneously.
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Bubble CPAP is a sort of special medical equipment for supporting of babies breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies’ work of breathing effectively, while keeping the autonomous respiration.
1.Assemble the main machine, humidifier and the optional compressor together, to save space.
2.Inside the Air-oxygen Blender, and the FIO2 is continuous and controllable.
3.Adjusting the oxygen concentration and the flow respectively.
4.It is easy to monitor the FIO2, to ensure the safety of oxygen.
5.High accuracy of CPAP regulating, combine the system pressure monitor with safety valve to ensure the safety of patient.
6.The main machine does not need electric power, and match with support arm.
7.The optional compressor adopts imported pump, with little water and low noise.
8.Match with humidifier that controlled by electric or automatically, to ensure the best situation of humidifier.
9.The light and diversified tubes and rhinobyons reduce the patient's WOB; the convenient fixed device reduces the compressor of patient's head and face, and the injure of nasal septum.
10.It is applied to PIIUC, NICU, PICU and first aid room widely.
Ventilation mode: CPAP mode
FIO2: 21%~100%
Flow: 0~18LPM
CPAP adjustment: 0~1.0kPa(0~10cmH2O)
Pressure monitor: 0~2.5kPa(0~25kPa)
FIO2: 21%~100%
Pressure safety valve: if the pressure in tubes over 1.5 times than adjusting parameter, the safety valve will open automatically.
Differential alarm: differential pressure between 0.05MPa~0.12MPa, sound alarm.
Low battery alarm: when the voltage reduce to 6.8±V0.5V,LCD will alarm “LOW BATTERY”。
Common parameter:
Size: W*H*D 24.7cm*17.5cm*21cm
Weight: about 6KG
Gas-source: 0.3MPa~0.4MPa
Previous:Medical for pediatrics Bubble CPAP neonatal ventilator machine Equipments MSLVM32
Next:Cost effective Pediatric ventilator ICU ventilaor machine MSLVM34