Basic Function
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
This CPAP system could provides continuous positive airway pressure based on Non-invasive ventilation , and used for treating infant slightly respiratory failure. But the infant should have spontaneous breath. This unit could apply in Pediatrics and Neonatology.
Basing on NCPAP ventilation mode
Offer properly adjusted O2 concentration
mechanically ventilated
CPAP ventilation mode keeps children spontaneous breath and reduces children breathing work, continues to provide CPAP mode of constant flow and limited pressure for newborn baby;
Delivery air/O2 mixture with properly adjusted O2 concentration and continuous positive pressure to premature baby, newborn baby and child, which will highly improve the safety and efficacy of oxygen therapy;
Equipped with built-in oxygen/air blender, ensuring O2 concentration adjustment to be stable ;
High quality oxygen sensor can monitor real-time O2 concentration , alarm over limitation, ensure safety of breathing O2;
Reliable CPAP control valve and advanced pressure monitoring system improve CPAP adjustment precision.
3’’display
Working condition
Air source O2、AIR
Air source pressure 280 kPa ~ 600 kPa
Power supply ~220 V±22 V, 50 HZ with air compressor
100-240V,50/60HZ(without air compressor)
Input power 900VA(with air compressor)
250VA (without air compressor)
Ventilation Mode
CPAP
Main technical parameters
Adjusting Parameter
Inhaled oxygen concentration 21 %~100 %
CPAP 0cmH2O~15 cmH2O
Continuous flow 2L/min~20L/min
Monitoring Parameter
Inhaled oxygen concentration 15 % ~ 100 %
CPAP 0 cmH2O ~ 60 cmH2O
Continuous flow 2 L/min ~ 20 L/min
Alarm and protection
The AC power cut-off alarm
Low air (oxygen) input pressure alarm
Air / oxygen input unbalanced pressure alarm
High oxygen concentration alarm
low oxygen concentration alarm
Pressure limit
The main structure-MSLVM26
Main Unit(gas parameter adjustment, display, security and alarm systems, oxygen and air mixing device, the oxygen concentration meter, the patient connector), medical air compressor (optional), gas supply ,tubing rack.
Accessories
Optional parts: humidifier with heating device, which could avoid dry gas harm for respiratory tract.
Air compressor:
Optional air compressor
Input power: 900VA
Hanging bracket:
Made by Aluminum Alloy, very stable and durable.
Recycling Breathing Circuit:
Made of Silica Gel, could be recycled use
High-pressure pipe:
Very strong and durable
Nasal Cannula
MSLVM25 Detail Configuration
No. Name Spec Quantity Unit
1 CPAP ventilation system 2.782.011 1 Unit
2 Air compressor connection Hose 4.472.003 1 PCS
3 High pressure O2 hose 4.472.004 1 PCS
4 Hose for airway pressure 4.472.006 1 PCS
5 Filter AF1500 1 Unit
6 Humidifier SH330 1 Set
7 Hanging Bracket 1
8 Power line 0.6M 1 PCS
9 Power line(006) 4M 1 PCS
10 Fuse T1A 4 PCS
11 Fuse T2A 2 PCS
12 Fuse T6.3A 2 PCS
13 Fuse T10A 2 PCS
14 User’s manual 1 PCS
15 Oxygen Sensor OOM202-1 1 PCS
16 Certificate of approval 1 PCS
17 Packing list 1 PCS
18 Infant breathing Tube 1000mm 2 PCS
600mm 2 PCS
300mm 1 PCS
Water collector φ10 Children 2 PCS
connector 8.653.033 2 PCS
BN11/Babi-Plus Neonatal Breathing circuit 1 Set
Luer Taper 3/32(2.4 Inside Thread PC) 4 PCS
Previous:Near-infrared diabetes Foot Therapy device Equipment Wholesale MSLNM01
Next:Cost effective Infant CPAP system ventilator machine MSLVM26
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger