Compare endoscopic diagnosis and remedial method with traditional method, the former can alleviate affliction of patient immensely.
Use CO2 to expand abdominal cavity of patient to gain suitable observational condition and sufficient operation space.
Gas Insufflator amalgamates the latest technical safety standard, can afford different forms of admission pattern.
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
MSLCI02 CO2 Insufflator - Medical Equipment Supplier
Introduction and Description
Gas Insufflator is the primary instrument of artificial pneumoperitoneum.
Using Gas Insufflator, you can affuse high purity CO2 into abdominal cavity, block off abdominal wall and abdominal entrails by the gas to make a operation manipulate space. It can stop admission when reach the expected air pressure, maintain a certain amount gas so that the abdominal cavity is always in expected air pressure. Gas Insufflator can automatic aerate in to maintain the necessary space of operation manipulate when air pressure of abdominal cavity descend in operation manipulate ( such as CO2 of abdominal cavity suck out or seep so that the pressure of abdominal cavity descend when air leak or operation that needs sunction or exosomatic oversew ).
Compare endoscopic diagnosis and remedial method with traditional method, the former can alleviate affliction of patient immensely.
Use CO2 to expand abdominal cavity of patient to gain suitable observational condition and sufficient operation space.
Gas Insufflator amalgamates the latest technical safety standard, can afford different forms of admission pattern.
LPS low pressure admission system
MSLCI02 CO2 Insufflator - Medical Equipment Supplier
Model | MSLCI02 |
Name | CO2 Insufflator |
Supply voltage | ~220V 50HZ or ~110V |
Rated power | 40VA |
Set pressure range | 5mmHg~25mmHg |
Set flow range | 2L/min--40L/min |
Function | LCD display,Waming |
Safety classification | Type I Model BF |
Run mode | Continuous load/intermittent operation |
Noise | ≤50dB |
Temperature | +10℃~+40℃ |
Relative humidity | 30%~75% |
Atmospheric pressure | 70KPA~106KPA |
Host size | 400*360*130mm |
Weight | 10kg |
MSLCI02 CO2 Insufflator - Medical Equipment Supplier
Display and manifestation
Preinstall pressure
According to actual needs, press pressure preinstall descending and ascending key, adjust preinstall pressure.
Actual abdominal pressure
When Gas Insufflator under opening circumstance, Gas Insufflator can show Actual intracavity pressure
When reduce pressure to less than actual intracavity pressure
Under the circumstance that reflux of gas get into Gas Insufflator ( the danger of being polluted )
In order to reduce pressure rapidly, should make use of any exit of body to exhaust air ( For example :open a piston )
MSL TEAM picture
MSL Certificate
MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.
Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.
Please feel free to contact cindy@medicalequipment-msl.com.
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger