Ready to measure within 5 seconds
With NDIR infrared mainstream technology inside
Rugged,shock resistant and water resistant design
Continuous and real-time capnogram of EtCO2 values
Simple interface for quick set-up and easy to operating
With two standard AAA lithium batteries
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Introduction
EtCO2 measure the exchange of carbon dioxide in the lungs upon exhalation, which has been proven as an effective means to diagnose multiple respiratory conditions. End tidal carbon dioxide (EtCO2) is also becoming one of the vital signs that many healthcare professionals will test for during routine and emergency procedures. Understanding the growing need for dependable EtCO2 monitors, Infinium Medical is proud to offer capnograph monitors that feature state-of-the-art technology and are highly versatile. Tested and retested by trained medical experts in a wide range of real-world scenarios, our capnography monitoring equipment will provide the accurate results you need when and where you need them, whether you're in the trenches of an ICU or in a remote medical triage setting.
1.CO2:0-99mmHG
2.RR :3-150bpm
3.Display 4.parameter:Etco2,RR,Capnogram
5.Degree of protection:IP33
Rapid Measurement
It is ready to measure within 5 seconds; with End-tidal CO2 value shown after the first breath and Respiratory rate value shown after the second breath, then updating every breath thereafter.
Reliability
It is built with NDIR infrared mainstream technology inside and performs a functional self check each time it is powered on.
Simply switch on, then connect to an ET-tube or breathing circuit and start measuring.
It has a rugged,shock resistant and water resistant design to provide the user with a reliable monitor for emergency situation.
Airway Adapter
It quickly and directly connects to endotracheal tubes, face masks or laryngeal masks via the airway adapter which are designed to make connection so simple and straight forward. We have two type airway adapter-disposable airway adapter.
Features
I Capnogram
Continuous and real-time capnogram of EtCO2 values.
I Easy-to-use
Simple interface for quick set-up and easy to operating.
I Audible and visual alarms
For no breath detected,no adapter, check adapter,and adjustable high and low EtCO2 alarm.
I Battery
With two standard AAA lithium batteries.
Performance
RANGES
CO2 0-99 mmHg
0-9.9 kPa 0-10%
RR 3-150 bpm
ACCURACY (STANDARD CONDITIONS)
CO2 0-40 mmHg ±2 mmHg; 41-99 mmHg ±6% of reading
0-5.3 kPa ±0.3 kPa; 5.4-9.9 kPa ±6% of reading
RR ±1 bpm
BATTERIES
Type Two AAA Alkaline or Lithium
Battery life 6 hours (Alkaline)
10 hours (Lithium)
ENVIRONMENTAL
Operating temperature 0to40 C (32 to 104 T)
Operating atmospheric pressure 70-120 kPa
Operating humidity 10-95% RH, non-condensing
Storage temperature -20 to 70 C (-4 to 158T)
Storage atmospheric pressure 50-120 kPa
PHYSICAL CHARACTERISTICS
Dimensions 1.7 x 1.7 x 2 in (4.4 x 4.5 x 5.2 cm)
Weight 2.3 oz (66 g) (with Alkaline batteries)
OTHERS
Display parameter EtCO2, RR, Capnogram
CO2 unit mmHg, kPa, % (selectable)
Data output Bluetooth (optional)
Degree of protection IP33
Address:85th, Baiyun Road, Shiqiao Street, Panyu District, GuangZhou City Sitemap
Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Mob:+86 13168310539
Connect us in Whatsapp or Facebook Messenger
Messenger