24 hour non-stop cooling Chemistry Analyzer machine URIT-8021A
	Random access, 200 tests per hour
	Durable ceramic syringes
	Select best test point by reaction curve, create
	new factor automatically
	Support bi-direction LIS and HIS interface
	
	Durable ceramic syringes Chemistry Analyzer machine URIT-8021A Features 
	24 hour non-stop cooling system to ensure reagent at 2-8℃
	
		Durable ceramic syringes to ensure accuracy & precision
	
		High accurate optical system
	
		Collision protection in both vertical and horizontal directions, stop & alarm automatically
	
		once touching barrier, not affect former tests
	
		Automatic eligible cuvettes detection & selection
	
		Select best test point by reaction curve, create new factor automatically
	
		Support LIS interface 
 
	
	Automatic eligible cuvettes detection Chemistry Analyzer machine URIT-8021A Specifications
	Assay methods: End Point, Kinetic, Fix time etc.
	Principle: Photoelectric colorimetry
	Light Source: Halogen lamp 12V/20W
	Photometry range: 0~3.2Abs
	Resolution: 0.0001Abs
	Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm
	Throughput: 200 tests/hour
	Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)
	Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions
	Reaction tray: 120 reaction cuvettes
	Sample volume: 2~100ul, with 0.1ul increment
	Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment
	Minimum reaction volume: 180uL
	Maximum reaction time: 10 minutes
	Water Consumption: Less than 5L/hour under working status
	Clean unit: 8-step auto-washing system with detergent
	Calibration: Calibration reset, select best test point by reaction curve, no need second calibration
	Line/non-line;multi-standards assay
	Control rules: Westgard multi-rule, Cumulative sum check, Twin plot
	3 level controls for each ifem, analyxing and printing QC analysis diagram
	Temperature control: incubator 37±0.1℃
	Power supply: AC 230(1±10%)V, 50/60Hz, 500VA
	Ambient: Operating temperature: 10~30℃
	Relative humidity: ≤85%
	Atmospheric pressure: 86~106kPa 
	 
	 
	
		High performance mixer design 
 
	Absence of cross contamination
	Optimal homogenization in minimum time
	Mixing immediately after dispensing of sample and the second reagent
	 
	 
	
		High accurate, close, static state optical system
	
		Spot photometry with high speed digital transmission system
	
		Durable cuvettes
	
		8-step auto-washing system with detergent and deion-water to ensure
	
		cuvettes clean and decrease cross contamination
	
		120 reaction cuvettes located in a constant temperature incubator
	
		Low consumption, open reagent design