TYPE: 300ma xray equipment/xray machines
BRAND NAME: MSL
MODEL NUMBER: MSLCX14
PLACE OF ORIGIN: CHINA (Mainland)
Capacity: Two-phase 30KVA
power supply adjustable range: 380±10% at220V being adjustable continuously
Radiograph Voltage: 50-125KV being adjustable continuously
Radiograph time: 0.04~6.35s 23grades together grading a according to R10 coefficient
Radiograph current: Small focus:50mA100mA, Big focus:50mA 100mA 200mA 300mA
Intemal resistance:0.75Ω(380V)0.25Ω(220V)
X-Ray tube Model: XD51.20-40/125
Travel in length: ≥500mm
Packaging detail : wooden case
Delivery detail: within 7-10 workdays after receipt of payment
300ma x-ray machine
can used for general radiography, Bucky radiography of body's head, chest, foot and hand, bones in lying.
300ma xray equipment/xray machines-MSLCX14
General radiography,Filter-ray-filter radiograph;Unit Configuration Control ,HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column ,Collimator Function.
The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones
in lying.
xray machines
Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling
MAIN TECHNICAL INDEXES
ITEM |
CONTENTS |
INDEX |
Demand of power supply |
Capacity |
Two-phase 30KVA |
Voltage Frequency |
380V/220V ±10%50HZ ±0.5Hz |
|
Intemal resistance |
0.75Ω(380V)0.25Ω(220V) |
|
power supply |
Adjustable range |
380±10% at220V being adjustable continuously |
Radiograph |
Voltage |
50-125KV being adjustable continuously |
current |
Small focus:50mA100mA, Big focus:50mA 100mA 200mA 300mA |
|
time |
0.04~6.35s 23grades together grading a according to R10 coefficient |
|
High-voltage generator |
Capacity |
20KVA(instantaneous) |
Max DC output voltage |
125KV |
|
Max DC output current |
300mA |
|
X-Ray tube |
Model |
XD51.20-40/125 |
Focus |
Small focus 1×1mm big focus2×2mm |
|
Radiographic table |
Length*width*height of bed surface |
2000mm×665mm×700mm |
Moving range of bed surface |
640mm in Length, 200mmin breadth |
|
Ray-filter of table |
Travel in length ≥500mm |
|
Grid density N=28 |
||
Convergence distance f.=100cm |
||
Grid ratio r=8 |
||
Column of X-ray tube unit |
Moving Longitudinally along Radiographic table |
1000mm or 1800mm |
Distance to friend as moving up and down (along column) |
650~1800mm |
|
Rotary around the center of cross arm |
±180° |
|
Rotary around the shaft line of X-ray annular tubes |
-10°~60°~ +120° |
|
Max size of cassette |
356mm×432mm(14×17) |
Full body radiation protective suit | Radiation proof suit - MSLLS01
X-ray lead gloves | Nuclear gloves - MSLRS04
Lead leg pads | X ray foot guard - MSLRS02
Cheap X-ray lead glasses for sale - MSLLG02
Hospital or medical rubber sheet - MSLLR01
4 Casters X-ray lead screen - MSLLD02
Discount Medical x-ray film with CE for sale - MSLMF01
Developing solution | Film developing liquid - MSLDS01
Green sensitive x ray film with CE for sale - MSLMF02
X ray lead glass | X ray protection glass - MSLLG01
Lead free apron | x-ray protection clothing - MSLLA01
X-ray intensifying screen - MSLMF04
X ray lead protective aprons-MSLLA04
Address:Room 405-407,South China Building,West Fuhua Road,Shiqiao Town,Panyu District,Guangzhou,China Sitemap
Tel:+86-20-84899760 Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Skype:msl_saler01 Mob:+86 138 2644 8637
Connect us in Whatsapp or Facebook Messenger
Messenger