TYPE: 125ma x ray equipment for radiography and fluoroscopy for sales
BRAND NAME: MSL
MODEL NUMBER: MSLCX19
PLACE OF ORIGIN: CHINA (Mainland)
Specification of spot film:5''*7'',8''*10'',10''*12"
Radiograph time: 0.04-6.3s,24grades together
Fluoroscopy Voltage: 50-90KV
Distance between the focus to the screen:830 mm (max) 630 mm (min)
Packing size: 216*95*100cm and 131*69*115cm
Packaging detail: wooden case
Delivery detail: within 7-10 workdays after receipt of payment
1.fluoroscopy and radiography
2.suitable for hospitals and health centers
3.single table and single tube
Application
Fluoroscopy,Digestive track spot film radiography,General radiography,
Filter-ray device radiography
Unit Configuration
Control,HT generator unit,Ht cable,X-ray tube unit,Diagnostic table,Column
125ma x ray equipment for radiography and fluoroscopy for sales-MSLCX19
x ray equipment sales
MAIN CHARACTERIDTICS
1.Single table and single tube
2.Design according to the electric mechanism of middle-size machine ,The function is reasonable
3.The high-tension system is of split structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation
4.Supply voltage (V),roentgenoscopy , radiography (kv) and stepless adjust able
5.Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output
6.Equipped with the capacity limitation and portection circuit and Kv mA S interlock limitation and protection
7.Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly,
8.Diagmafic table is of electric back rotation and is equipped with vibrating filter-ray device
9.The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy
10.The column post hast has the bottom track only, which is easy while installation
MAIN TECHNICAL INDEXES
ITEM |
CONTENTS |
MSLCX19 |
Upright post(column) |
Moving longitudinally(along the bottom track) |
1500mm |
landscape orientation movement |
360mm |
|
Moving up and down |
720-1720mm from focus to ground |
|
Supply power |
Voltage |
220V/380(single phase ) |
Frequency |
50Hz±0.5Hz |
|
Capacity |
10KVA |
|
Intemal resistance |
380v:2Ω,220V:0.6Ω |
|
Max DC output voltage |
90KV |
|
Max DC output current |
125mA |
|
Fluoroscopy |
Voltage |
50-90KV |
current |
≤5mA |
|
Radiograph |
Voltage |
50-90KV |
current |
Small focus 15mA , big focus30mA 60mA 100mA |
|
spot film |
100mA(fixed) |
|
time |
(0.04-6.3s,24grades together) |
|
High-voltage generator |
Capacity |
7KVA |
X-Ray tube |
Model |
XD4-2.9/100 |
Focus |
Small focus 1.8mm big focus4.3mm |
|
Diagnostic table |
rotary angle |
+90°~0~-5° |
specification of spot film (stomach and intestines photography) |
128×179mm(5”×7”) |
|
205×254mm(8”×10”) |
||
254×305mm(10”×12”) |
125ma x ray equipment for radiography and fluoroscopy for sales |
|||
Focus of X-Ray tube |
Radiograph mA |
Max Radiograph KV |
Max exposure time allow |
Small focus |
15mA |
90KV |
6.3S |
Large focus |
30mA |
90KV |
6.3S |
60mA |
90KV |
6.3S |
|
100mA |
85KV |
2.5S |
|
125mA |
82 KV |
1.0S |
Full body radiation protective suit | Radiation proof suit - MSLLS01
X-ray lead gloves | Nuclear gloves - MSLRS04
Lead leg pads | X ray foot guard - MSLRS02
Cheap X-ray lead glasses for sale - MSLLG02
Hospital or medical rubber sheet - MSLLR01
4 Casters X-ray lead screen - MSLLD02
Discount Medical x-ray film with CE for sale - MSLMF01
Developing solution | Film developing liquid - MSLDS01
Green sensitive x ray film with CE for sale - MSLMF02
X ray lead glass | X ray protection glass - MSLLG01
Lead free apron | x-ray protection clothing - MSLLA01
X-ray intensifying screen - MSLMF04
X ray lead protective aprons-MSLLA04
Previous:X-ray machine 100ma for sale-MSLCX20
Next:200ma x ray medical equipment|x ray machine suppliers-MSLCX18
Address:Room 405-407,South China Building,West Fuhua Road,Shiqiao Town,Panyu District,Guangzhou,China Sitemap
Tel:+86-20-84899760 Email:Cindy@medmsl.com / cindy@medicalequipment-msl.com Skype:msl_saler01 Mob:+86 138 2644 8637
Connect us in Whatsapp or Facebook Messenger
Messenger