12 Channel Holter ECG monitoring system MSLHT02
ECG monitoring system MSLHT02 Brief Introduction
MSLHT02 Dynamic ECG Systems contains recorder & analysis software. Recorder is
an easy- to -use unit, which collects 12-lead ECG waveform synchronously
and records continuously for 48 hours.
12 Channel ECG monitoring system MSLHT02 Recorder features
1. Compact design.
2. OLED display.
3. Function of event marking.
4. Removable TF card(volume: up to 2GB).
5. One "AAA" size battery can collect the ECG data of 48-hour.
6. Ten electrodes synchronously collect the 12-lead ECG data.
The features of software
1. With 12 leads synchro analysis , QRS search can be more exactly
2. There are more than 10 templates as atrial premature beat module,
ventricular premature beat module, long interval module, atrial flutter module,
atrial fibrillation module etc.and multiplicate User-defined templates could
almost identify every kind of pathologic waveforms
3. Flexible atrial fibrillation analysis, so that physicians can use full, segmented
automatic, manual analysis of atrial fibrillation, make the analysis more quickly and accurately
4. Powerful pacemaker analysis, on the AAI, VVI, DDD etc. all pacemaker analysis
5. Any period of single lead or 12-leads ECG can be reviewed at any time
with the function of fast waveform review and analysis
6. Analysis of heart rate variability with short-range 5 minutes and long-range
1 hour and full analysis of heart rate variability
7. A one-stop printing operation, report printing process is convenient and quick
8. "Heart rate turbulence" analysis can predict the risk of death in patients with myocardial infarction
9. "T Wave alternation" analysis is a important index on judging and preventing Arrhythmia
10. The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.
Standard
• Lead mode: standard 12-lead
• Sampling accuracy: 12bit
• Recording time: 48h
• Scale voltage: 1mV±5%
• Standard Sensitivity: 10mm/mV±5%
• Noise level: ≤30µV
• CMRR: ≥60dB
• Low-frequency characteristics: Time constant≥3.2s
• Enduring polarization voltage:±300mV DC polarization voltage,sensitivity shift≤±10%
• Least measure signal: 50 µV p-p
• Product safety type: Type B applied part(Internally powered equipment)
Accessories:
• ECG lead wires(12-Lead)
• ECG electrode(20 per bag)
• Micro sd Card Reader(1)
• Disk(1)
• Host bag(1)
• User manual(1)
• softdog
Physical Characteristic
Dimension: 80.5mm(L) *59.5mm(W) *22mm (H)
Weight: 61.5g (Without battery)